GRP Sectional Water Tank for Residential Secondary Water Supply
Key Points Tag :
With the rapid development of global urbanization, the number of high-rise residential buildings and commercial buildings continues to increase. Water supply systems are required to provide safe, stable, and efficient continuous water supply. In urban areas, municipal water pressure is often affected by factors such as pipeline distance, building height, and peak water consumption. Therefore, secondary water supply systems have become an essential water supply solution for modern high-rise residential buildings. In China, almost all urban high-rise residential buildings adopt this type of water supply system.
As one of the three major types of modular water tanks, GRP/FRP water tanks are key water storage equipment in secondary water supply systems. Integrated with building water supply pipelines and fire protection facilities, they form a complete pump room water supply system. They are mainly used for domestic water storage and balancing fluctuations in water demand.

Secondary Water Supply Tank

Residential Domestic Water

Building Fire Protection
Reference for Matching Water Tank Panel Thickness and Height Values
| Height | Bottom Board | Side 1 | Side 2 | Side 3 | Side 4 | Side 5 | Top board |
|---|---|---|---|---|---|---|---|
| 5000 mm | 20 mm | 20 mm | 16 mm | 14 mm | 12 mm | 10 mm | 5 mm |
| 4500 mm | 20 mm | 20 mm | 16 mm | 14 mm | 12 mm | 10 mm | 5 mm |
| 4000 mm | 18 mm | 18 mm | 14 mm | 12 mm | 10 mm | 5 mm | |
| 3500 mm | 16 mm | 14 mm | 12 mm | 10 mm | 8 mm | 5 mm | |
| 3000 mm | 14 mm | 14 mm | 12 mm | 8 mm | 5 mm | ||
| 2500 mm | 12 mm | 12 mm | 10 mm | 8 mm | 5 mm | ||
| 2000 mm | 12 mm | 10 mm | 8 mm | 5 mm | |||
| 1500 mm | 10 mm | 10 mm | 8 mm | 5 mm | |||
| 1000 mm | 10 mm | 10 mm | 5 mm |
- FRP/GRP panels are manufactured using standard molds. Common panel sizes include 1×1 m, 1×0.5 m, and 0.5×0.5 m.
- The maximum tank height is 5 meters. For tanks exceeding 4 meters in height, external C-channel steel reinforcement is required.
- Panel thickness varies according to the tank height and pressure resistance requirements, depending on the overall tank design.
Working Principle of Secondary Water Supply System for High-Rise Residential Buildings
A high-rise residential secondary water supply system usually consists of a GRP water tank, booster pump system, control system, and building water distribution network. The tank capacity and dimensions are generally determined during the initial building design stage, with installation space reserved in advance. The water tank is then assembled on-site through a modular installation process.
The system operation process is as follows:
Municipal Water Supply → GRP Water Storage Tank → Booster Pump System → Building Water Distribution Network → Residential Users
During normal operation, municipal water first enters the GRP water tank for storage. When residential water demand increases, the booster pump automatically starts according to pressure monitoring and water consumption requirements, delivering pressurized water from the tank to different floors of the building.
This system effectively solves common problems in high-rise buildings, including insufficient water pressure, inadequate water supply during peak hours, and unstable water distribution. In addition to the booster water supply system, these buildings usually require separate fire emergency water storage tanks to meet fire protection requirements.
Applications of GRP Water Tanks in High-Rise Residential Buildings
Modular water tanks are widely used in various high-rise residential and commercial building projects due to their flexible installation advantages, including:
- High-rise residential buildings
- Apartment buildings
- Residential communities
- Mixed-use commercial and residential complexes
- Hotels
- Hospitals
- Schools
Depending on local standards, project requirements, and cost considerations, different regions may choose GRP water tanks, stainless steel water tanks, or hot-dip galvanized steel water tanks. Among them, GRP water tanks are widely used in Southeast Asian markets.
High-rise buildings usually require water tanks to be installed in underground equipment rooms, rooftop equipment areas, or dedicated water tank rooms. These locations often have limited space and narrow access routes. Modular water tanks such as GRP tanks do not require large lifting equipment and are especially suitable for basement installations and space-restricted areas.


Why Choose GRP Water Tanks for High-Rise Residential Buildings?
1. Excellent Corrosion Resistance
Water tanks in high-rise residential buildings are commonly installed in humid environments such as underground equipment rooms. The exterior of the tank is exposed to moisture for long periods, while the interior remains in direct contact with water. Therefore, corrosion resistance is an essential requirement for residential water storage tanks.
GRP materials provide excellent corrosion resistance and are especially suitable for tropical climates, high-humidity regions, and coastal building projects.
Key advantages include:
- Preventing rust contamination
- Suitable for humid environments
- Reduced maintenance frequency
- Extended service life
2. Safe and Hygienic Domestic Water Storage
Residential water tanks are mainly used for daily domestic water supply, and water quality directly affects residents’ health and living standards.
GRP water tanks are manufactured using food-grade materials with smooth inner surfaces that reduce dirt accumulation and facilitate cleaning. Unlike steel water tanks, GRP tanks do not react with water and are not affected by corrosion, effectively reducing the risk of secondary contamination.
Applications include:
- Residential domestic water supply
- Centralized apartment water supply
- Domestic water storage for commercial buildings
Water Tank Structure
- Panels (including bottom panel, wall panels, roof panel, and manhole cover);
- Internal Components (including internal ladder, tie rods, supports, flanges, and rubber seals);
- External Components (including external ladder, angle iron, tie plates, bolts, and nuts);
- Base (Concrete beam,C-channel steel).
Physical Properties
| Physical Property | Standard Requirement | Test Result |
|---|---|---|
| Tensile Strength | ≥60 MPa | 66.5 MPa |
| Flexural Strength | ≥120 MPa | 184 MPa |
| Flexural Modulus | ≥10 GPa | 12.8 GPa |
| Barcol Hardness | ≥60 HBa | 63.9 HBa |
| Water Absorption | ≤0.5% | 0.13% |
| Glass Fiber Content | ≥25% | 29% |
Reliable Water Storage Solution for Modern Buildings
GRP water tanks for high-rise residential secondary water supply systems provide reliable, safe, and long-term water storage solutions with advantages such as corrosion resistance, easy installation, and large storage capacity.
According to different project requirements, customized GRP water tank solutions can be provided based on:
- Building height
- Number of residents
- Daily water consumption
- Installation space
- Local climate conditions
GRP sectional water tanks are an ideal choice for modern residential buildings requiring stable and efficient secondary water supply systems.
| Product Name | Fiberglass Water Tank, FRP Water Tank, GRP Water Tank |
|---|---|
| Material | FRP, GRP |
| Grade | Food Grade |
| Origin | China |
| Color | white |
| Panel Size | 0.5*0.5m, 1*0.5m, 1*1m, 2*1m |
| Panel thickness | From 5mm to 24mm |
| Certification | ISO3834, ISO9001 |
| HS Code | 730990 |
| Capacity | 1000Litres -Infinity |
| Foundation | Concrete Foundation, U-Steel Bottom Bas |
| Installation | Sitting Type, Welding |
| Production Capacity | 2000Ton/Month |
| Transport Package | Pallet Box, Plywood Pallet, Steel Frame |
| Sample | Provided |
| After-Sale Service | Online Technical Support |
Professional Design Capability


Packing & Shipping
- The products are packaged using iron frames or plywood boxes to ensure they are not damaged during land transportation and shipping.
- Each individual package is covered with a waterproof film to prevent exposure to moisture during long-term sea transportation.
- Accurately label all panels and accessories to facilitate quick installation by customers.

Water Tank Panel Packaging 1
Plywood Box

Water Tank Panel Packaging 2
Steel Frame Support

Water Tank Panel Packaging 3
HDG

Water Tank Panel Packaging 4
GRP/FRP

Large Components
Loose Packing

Small Accessories Packaging
Plywood Box

Full Container Shipment
Steel Frame Packaging

Full Container Shipment
Simple Packaging
Qualification & Certification
Our water tank products are designed and manufactured in strict accordance with domestic and international standards and have passed multiple industry-recognized certifications, including ISO 9001 Quality Management System certification, food-grade stainless steel material standards (SUS304 / SUS316), and drinking water safety-related certifications.




Delivery
- For standard water tank less than 200m3, it would be 3-5 days;
- For non-standard water tank and customized water tank according to client’s specific requirements, it would be 7 to 15 days.
- The final delivery time shall be subject to the actual order confirmation.